Vue de la page 0
1
WARNING
DO NOT INSTALL THE ACTUAL
SMOKE ALARM IN NEW OR
RENOVATED BUILDINGS UNTIL ALL
WORK IS COMPLETED (INCLUDING
FLOOR COVERINGS) AND
BUILDING HAS BEEN FULLY
CLEANED.
(Excessive dust & debris from building work can
contaminate the smoke chamber and cause
problems).
An installed smoke alarm must be removed or
covered fully (with a plastic bag or similar)
before renovations begin.
'Ei Electronics 2003 P/N B15026 R0
RADIO SMOKE ALARMS
with WIRELESS INTERCONNECT
INSTRUCTION LEAFLET
Contains vital information on unit operation and installation.
Read and retain carefully. If you are just installing the unit, this
leaflet MUST be given to the householder.
MODELS:
Ei 405 - Replaceable 9V Battery
Ei 405C - Replaceable 9V Battery &
hard wired interconnect option
Ei 405TY - 10 Year Lithium Batteries built-in
Ei 405TYC - 10 Year Lithium Batteries built-in
& hard wired interconnect option
All with Optical Smoke Sensor
1
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - RADIO SMOKE ALARMS

1WARNINGDO NOT INSTALL THE ACTUALSMOKE ALARM IN NEW ORRENOVATED BUILDINGS UNTIL ALLWORK IS COMPLETED (INCLUDINGFLOOR COVERINGS) ANDBUILDING HAS BEEN F

Page 2 - 1. READ THIS FIRST

10Program Procedure1. Press the test button on the first installed unit three timeswithin 1.5 seconds. The blue light will come on momentarilyeach ti

Page 3 - 2. INTRODUCTION

11Clear the serial numbers learned by:- disconnecting the battery- waiting 10 seconds- holding the test button down while re-connecting the batterysna

Page 4 - 3. LOCATING YOUR SMOKE ALARM

12The unit can be quickly removed from the program mode byholding down the Test & Locate buttons simultaneously.(The house coding can be remov

Page 5

136.8 Automatic Self-TestThe smoke chamber automatically tests itself every 40 sec-onds. If the chamber is degraded it will beep without the redlight

Page 6 - Figure 5 Figure 6

14(ii) Low Battery beeps (Model Ei 405TY & Ei405TYC only)The unit is giving a short beep every 40 seconds and the redlight flashes at the same tim

Page 7

15A maximum of 250 metres (820ft) of signal cable can be used,(maximum resistance between detectors 50 ohm). The unitsare interconnected by wiring all

Page 8 - Figure 7

16¥ Constant exposure to high or freezing temperatures, highhumidity or a high level of nuisance alarms may reduce thelife of the battery.¥ Nuisance a

Page 9

17¥ Smoke Alarms may not detect every type of fire to give suf-ficient early warning. They are particularly ineffective with:fires caused by smoking

Page 10

188.2 FIRE SAFETY HINTSStore petrol and other flammable materials in proper contain-ers.Discard oily or flammable rags.Always use a metal fireplace sc

Page 11

19The Home Office states (in FB2):If your home has more than one floor, at least one alarmshould be fitted on each level. In this case, a combination

Page 12

1. READ THIS FIRSTA Smoke Alarm is an early warning device. Used correctly itcan give you and your family valuable extra time to escape.¥ Models Ei

Page 13

2013. TECHNICAL SPECIFICATIONBattery: Replaceable 9 Volt Alkaline Duracell (Ei405 & 405C only) MN1604, Energizer 522 or Eveready 522. Battery Li

Page 14 - 7. HARDWIRE INTERCONNECTION

21RF RECEPTIONExternal Alarm RF Signal: Turns on horn without red light flashinguntil it fails to receive alarm confirmationfor 11 seconds. Stops hor

Page 15 - 8. IMPORTANT SAFEGUARDS

22The blue light will turn on as the button ispressed. Program Mode: Number of fast flashes every 5 secondsindicates number of units (includingremote

Page 18 - OPTICAL OR IONISATION ?

3¥ If the Alarm beeps without the red light flashing at thesame time then clean unit as this is the automatic test fea-ture indicating the chamber is

Page 19

4excellent, particularly at night, as it rapidly identifies wherethe fire is located. This is ideal for larger systems as the dis-turbance in the h

Page 20 - 13. TECHNICAL SPECIFICATION

Figure 2: Single storey dwellingFigure 3: Single storey dwelling with separate sleepingareas.In houses with more than one sleeping area, Smoke Alarmss

Page 21

63.3 Recommended ProtectionFor recommended protection you should put individualSmoke Alarms in all the rooms where fire is most likely tobreak out (ap

Page 22

74.3 On a sloping CeilingIn areas with sloping or peaked ceilings install your SmokeAlarm 0.9m from the highest point measured horizontally (seefigur

Page 23

8If there are frequent nuisance/false alarms it may be neces-sary to re-locate the device away from the source of thefumes.If you installed the smoke

Page 24

9If the alarm fails to sound, follow this checklist:¥ Check the age of the unit - see the replace by label onbase of unit.¥ Check the battery snaps